CleanSpace Full Face Mask
PRODUCT CODE: PAF-1106 (Small), PAF-1014 (Medium/Large)
PRODUCT NAME: CleanSpaceTM Full Face Mask
DESCRIPTION:
The CleanSpace Full Face Mask (PAF-1014) is designed for use with the CleanSpace Ultra (PAF0070) and CleanSpace EX (PAF-0060) PAPRs. It is suitable for heavy, long term work or exposure. The Full Face Mask is positive pressure with a silicone outer visor seal and silicone Orinasal Inner Mask (PAF-1022, PAF-1027) for superior respiratory protection. The Orinasal Inner Mask Small (PAF1022) comes with every CleanSpace Full Face Mask.
The CleanSpace Full Face Mask is compatible with the CleanSpace Ultra and CleanSpace EX power units, the full range of standard CleanSpace Particulate Filters, Combined Gas Filters and pre-filters.
Approvals Standard & Classification*
EN 12942:1998+A2:2008 TM3
AS/NZS 1716: 2012 PAPR-P3
IEC 60529 IP-66
IEC 60079-0:2017 Ex ib IIIB T150 Db
IEC 60079-11:2011
AS/NZS 1337.1:2010 High Impact Resistance
IP Rating 66 – When used with CleanSpace ULTRA (original) and CleanSpace EX
*Specific classifications is dependent on filter used.
Features:
• Visor: Scratch-resistant and solvent-resistant coating
• Wide panoramic visor
• Silicone cushion seals to the face for optimum protection and comfort
• Recommended for applications where face protection and eye protection is required
• Suitable for long periods of wear
• Mylar speech diaphragm for clear communication
• Positive pressure airflow prevents fogging
• Inner mask has a unique clip-in/clip-out design and is easily removed for cleaning
• Built in Adaptor for TSI portacount mask fit testing
• Accessories available (sold separately): Spectacle kit and visor protection tears offs
Specifications:
• Product Weight: 700g
• Product Dimensions: 240mm x 220mm x 280mm
Materials:
Hard coated polycarbonate visor | nylon mask clips | high strength silicone harness | stainless steel buckle roller | silicone face seal and inner mask cushion | Mylar speech diaphragm | polycarbonate exhalation valve cover | impact-modified reinforced polypropylene exhalation valve housing | silicone O-rings
Cleaning, Use & Storage Conditions:
• Cleaning: warm soapy water and soft, lint free cloth or industrial washer
• Do not use solvents, hot water, bleaching or chemical agents
• Use temperature range: -10°C to +45°C (14°F to +113°F) at < 90% relative humidity
• Storage conditions: +10°C to +30°C (+50°F to +86°F) at < 75% relative humidity
• Store away from direct sunlight, grease, and oil
Applications:
Specifically designed for use with decontamination operations, particularly where showering is required; long term use in areas demanding very high levels of protection; tasks where eye protection is required.
Examples: Mining, Welding, Manufacturing, Smelting, Construction, Recycling Plants, Emergency Service, Agriculture, Processing Plants, Grinding.
The CleanSpace ULTRA (original) and CleanSpace EX with the CleanSpace Full Face Mask (PAF1106 / PAF-1014) are suitable for chemical applications where decontamination showers are used.
Refer to Filter Selection Table for expanded information on applications.
Applications for Intrinsically Safe approved sites:
Combustible Flyings and non-conductive dust environment requiring “High” equipment protection Level (Db) and level “ib” ignition protection, where the presence of such dusts is likely to occur (Zone 1).
Limitations:
CleanSpace respirators are PAPRs - air filtering, fan assisted, positive pressure systems and designed to be worn in environments where there is sufficient oxygen to breathe safely. Do not use CleanSpace respirators in immediately dangerous to life or health (IDLH) atmospheres, to protect against gases/vapours that cannot be filtered or in oxygen enriched or deficient atmospheres.
CleanSpace full face masks are not intrinsically safe certified.
| Domestic Shipping (Continental U.S.) | |||
| Orders $149+ | Expedited Shipping | Free | 3-5 Days |
| Orders $0-$149 | 2Day® | Paid by Customer | 2 Business Days |
| Ground® | Paid by Customer | 1–7 Business Days | |
| SmartPost® | Paid by Customer | 2–7 business days | |
| Standard Overnight® | Paid by Customer | 1 Business Day | |
| International Shipping | |||
| All Orders | International Priority® | Paid by Customer | 1-3 Business Days |
| International Economy® | Paid by Customer | 4 - 6 Business Days | |
Trusted By:
EXPLORE OUR COLLECTIONS
About This Product
The gloves. com CleanSpace Full Face Mask is built for long, demanding work where you need powered respiratory protection plus full face and eye coverage.This full-face design runs in positive pressure when paired with a compatible CleanSpace PAPR power unit, helping reduce inward leakage and keeping the wide panoramic visor clearer in humid, high-exertion tasks. The hard-coated polycarbonate visor has scratch-resistant and solvent-resistant coating, and the silicone face seal is made to sit comfortably during extended wear.
For better communication on the job, it uses a Mylar speech diaphragm. The oronasal inner mask clips in and out for easier cleaning, and there is a built-in adaptor for TSI PortaCount mask fit testing.
Pair it with the CleanSpace Ultra or CleanSpace EX power unit and choose the right particulate or combined gas filter for your hazard.
Technical Details
CleanSpace Full Face Mask for use with CleanSpace PAPR systems.Specs and materials:
- Compatibility: CleanSpace Ultra (PAF0070), CleanSpace EX (PAF-0060)
- Respirator type: PAPR, positive pressure full face mask
- Visor material: Hard coated polycarbonate
- Seal and harness: Silicone face seal, high strength silicone harness
- Clips and hardware: Nylon clips, stainless steel buckle roller
- Speech diaphragm: Mylar
- Exhalation components: Polycarbonate cover, reinforced polypropylene housing, silicone O-rings
- Weight: 700 g
- Dimensions: 240 mm x 220 mm x 280 mm
- Fit test port: Built-in adaptor for TSI PortaCount
Approvals and ratings:
- EN 12942:1998+A2:2008 TM3
- AS/NZS 1716:2012 PAPR-P3
- AS/NZS 1337.1:2010 high impact resistance
- IEC 60529: IP66 (with CleanSpace ULTRA (original) and CleanSpace EX)
- IEC 60079-0:2017 Ex ib IIIB T150 Db
- IEC 60079-11:2011
Cleaning and conditions:
- Cleaning: Warm soapy water and soft, lint free cloth, or industrial washer
- Do not use: Solvents, hot water, bleaching, chemical agents
- Use temperature: -10 C to +45 C, < 90% RH
- Storage: +10 C to +30 C, < 75% RH
Part numbers:
- Medium/Large: PAF-1014
- Small: PAF-1106
- Oronasal inner mask (small): PAF-1022 (included)
- Oronasal inner mask (alt): PAF-1027
Limitations:
- Use only where oxygen levels are safe
- Not for IDLH atmospheres, oxygen enriched or oxygen deficient areas
- Not for gases/vapours that cannot be filtered
- Full face masks are not intrinsically safe certified
How to Use
If you run decontamination work where showering is required, this full face mask is a strong fit. It is commonly chosen for operations that need full face and eye protection during long wear, especially when splashes, dust, or mixed hazards are part of the job.The mask pairs with CleanSpace Ultra or CleanSpace EX PAPR power units and supports the full range of CleanSpace particulate filters, combined gas filters, and pre-filters. Positive pressure airflow helps reduce fogging, and the wide panoramic visor improves visibility for detail work.
It also works well in heavy industry tasks like mining, welding, manufacturing, smelting, construction, recycling, grinding, and processing plants where face and eye protection are required at the same time.
Set it up with the right CleanSpace filter for your application, and add the spectacle kit or visor tear-offs if your site needs them.
Specifications
- Weight
- 700 g
- Best For
- Long-duration work where both respiratory protection and full face/eye protection are needed (mining, manufacturing, construction, welding, grinding, recycling, agriculture)
- Dimensions
- 240 mm x 220 mm x 280 mm
- Visor Type
- Wide panoramic hard-coated polycarbonate visor with scratch-resistant and solvent-resistant coating
- Fog Control
- Positive pressure airflow helps prevent visor fogging
- Use Limitations
- For environments with sufficient oxygen; not for IDLH atmospheres, oxygen-deficient/enriched areas, or hazards that cannot be filtered
- Inner Mask Design
- Silicone orinasal inner mask with clip-in/clip-out removal for easier cleaning
- Face Seal Material
- Silicone outer visor seal and silicone face seal for a secure, comfortable fit
- Fit Testing Support
- Built-in adaptor for TSI PortaCount mask fit testing
- Communication Feature
- Mylar speech diaphragm for clearer voice transmission
- Compatible Power Units
- CleanSpace Ultra (PAF0070) and CleanSpace EX (PAF-0060)
- Respirator System Type
- Powered air-purifying respirator (PAPR) full face mask (positive pressure)
- Compatible Filter Types
- CleanSpace particulate filters, combined gas filters, and pre-filters (sold separately)
- Ingress Protection Rating
- IP66 when used with CleanSpace ULTRA (original) and CleanSpace EX (classification depends on filter used)
- Certifications And Standards
- EN 12942:1998+A2:2008 TM3; AS/NZS 1716:2012 PAPR-P3; AS/NZS 1337.1:2010 High Impact Resistance; IEC 60529 IP66; IEC 60079-0:2017 Ex ib IIIB T150 Db; IEC 60079-11:2011